亚洲视频福利,亚洲丶国产丶欧美一区二区三区,H漫无羞遮无删减漫画免费,需要影音先锋下载的AV,国产日本一区二区精品,亚洲黄图

首頁(yè)
產(chǎn)品
卓越 ? 易用 ? 可靠
視頻
讓中國(guó)物聯(lián)網(wǎng)領(lǐng)先世界
搜索
歷史搜索
搜索發(fā)現(xiàn)
HOME > SERVICE > Problem > RTU

RTU common fault analysis table

2022-03-09 18:43:40| | 0
Serial Fault phenomenonPossible causes of failureterms of settlement
1Communication failure(1) Whether the RTU station address is inconsistent with the address set by the central station;(1) Reset the address;
(2) RTU does not work normally;(2) Replace RTU;
(3) The antenna direction of RTU radio station is not pointing to the central station;(3) Adjust the antenna;
(4) The radio station is not working properly.(4) Replace the radio station.
2Low communication success rate (large channel interference)(1) The feeder is not connected properly;(1) Connect the feeder;
(2) Large electromagnetic interference near RTU;(2) Avoid interference;
(3) RTU has no good ground wire.(3) Grounding.
3Communication succeeded, but the data is 0(1) The instrument has no output;(1) Check the instrument;
(2) The central station configuration is inconsistent with the RTU instrument channel;(2) Calculate the correct coefficient;
(3) Fault of RTU data acquisition part;(3) Check the input interface.
4The communication is successful, but the data is inconsistent with the field instrument(1) Instrument full scale;Bottom number: (12): 800;
(2) Setting of base number and coefficient of central station configuration;Coefficient: instrument full scale / RTU AI full scale.
(3) Incorrect reference voltage;
(4) The input type of AI is inconsistent with the instrument;
5The communication is successful, but the data jumps(1) Feeder interference;(1) Parallel capacitance;
(2) Large electromagnetic interference near RTU (such as frequency converter);(2) Avoid interference sources;
(3) AC power line interferes with 4 ~ 20mA signal.(3) Separate the wiring.
6RTU crash(1) RTU watchdog, imperfect software and hardware designField reset
(2) High electromagnetic interference near RTU
(3) RTU without good ground wire
7Output inoperative(1) The controlled equipment is damaged and the output electrical surge;(1) When receiving inductive load (such as motor or relay), it is necessary to use a suppression circuit;
(2) Loose or incorrect wiring;(2) Check the wiring. If it is incorrect, correct it;
(3) Output overload;(3) Check the load rate of power supply and output;
(4) There is a problem with the communication cable;(4) Check whether the CPU of PLC is forced;
(5) Station address setting error.(5) Reset the station address; Check the communication cable.


聯(lián)系銷售
銷售王經(jīng)理微信 銷售王經(jīng)理
微信公眾號(hào) 微信公眾號(hào)
服務(wù)熱線
400-6688-400
旅游| 钦州市| 富顺县| 新沂市| 托克逊县| 佳木斯市| 五华县| 横山县| 绥化市| 成都市| 长武县| 旺苍县| 宿松县| 东源县| 封开县| 桃源县| 正阳县| 咸宁市|